CAROLINA BIOGOLICAL SUPPLY CO -- SULFURIC ACID, 1N -- 6810-00D000338
===================== Product Identification =====================
Product ID:SULFURIC ACID, 1N
MSDS Date:01/04/1996
FSC:6810
NIIN:00D000338
=== Responsible Party ===
Company Name:CAROLINA BIOGOLICAL SUPPLY CO
Address:2700 YORK RD
City:BURLINGTON
State:NC
ZIP:27215-3387
Country:US
Info Phone Num:800-227-1150/910-584-0381(OUT SIDE)
Emergency Phone Num:800-227-1150/910-584-0381(OUT SIDE)
CAGE:59896
=== Contractor Identification ===
Company Name:CAROLINA BIOLOGICAL SUPPLY CO
Address:2700 YORK RD
Box:City:BURLINGTON
State:NC
ZIP:27215-3387
Country:US
Phone:800-227-1150/910-584-0381
CAGE:59896
============= Composition/Information on Ingredients =============
Ingred Name:SULFURIC ACID (SARA 302/313) (CERCLA)
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 3.71%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3/3 STEL; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RAT) IS 2140 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES-MAY CAUSE IRRITATION. SKIN-MAY
CAUSE IRRITATION. INGESTION-MAY CAUSE GASTROINTESTINAL DISCOMFORT.
INHALATION-MAY CAUSE IRRITATION TO RESPIRATORY TRACT.
Explanation of Carcinogenicity:NOT LISTED AS CAUSING CANCER BY IARC,
NTP OR OSHA.
Effects of Overexposure:HARMFUL IF SWALLOWED. CONTACT CAUSES EYE BURNS.
IRRITATING ON CONTACT WITH SKIN OR MUCOUS MEMBRANES; MAY CAUSE
BURNS.
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS OF THE
EYES, NOSE, THROAT AND SKIN.
======================= First Aid Measures =======================
First Aid:EYES-FLUSH WITH WATER FOR 15 MIN. GET MEDICAL ATTENTION IF
IRRIITATION PERSISTS. SKIN-THOROUGHLY WASH EXPOSED AREA FOR 15 MIN.
REMOVE CONTAMINATED CLOTHES. GET MEDICAL ATTENTION IF IRRITATION
PERSISTS . INGESTION-IF CONSCIOUS, GIVE PLENTY OF WATER.
IMMEDIATELY CALL A PHYSICIAN OR POISON CONTROL CENTER.
INHALATION-REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING IS HARD;
PERFORM CPR. KEEP WARM & QUIET.
===================== Fire Fighting Measures =====================
Extinguishing Media:USE MEDIA SUITABLE TO EXTINGUISH FIRE.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR FULL PROTECTIVE
EQUIPMENT AND NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCES TOXIC
FUMES. IS A STRONG OXIDANT & CONTACT WITH ORGANIC MATERIALS MAY
CAUSE FIRE & EXPLOSIONS. REACTS WITH MANY SUBSTANCES.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA OF SPILL. ELIMINATE ALL SOURCES
OF IGNITION. REMOVE ALL NON-ESSENTIAL PERSONNEL FROM AREA. CLEAN-UP
PERSONNEL SHOULD WEAR PROPER PROTECTIVE EQUIPMENT/CLOTHING. ABSORB
MATERIAL WITH SUIT ABLE ABSORBENT & CONTAINERIZE FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP IN TIGHTLY CLOSED CONTAINER.
STORE IN COOL, DRY AREA. DO NOT STORE NEAR METAL POWDERS OR OTHER
REDUCING MATERIALS.
Other Precautions:DO NOT GET IN EYES, ON SKIN, OR ON CLOTHING.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:A NIOSH/MSHA CHEMICAL CARTRIDGE RESPIRATOR
SHOULD BE WORN IF PEL OR TLV IS EXCEEDED.
Ventilation:LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION.
Protective Gloves:RUBBER, NEOPRENE, PVC OR EQUIVALENT.
Eye Protection:SPLASH PROOF CHEMICAL SAFETY GOGGLES.
Other Protective Equipment:LAB COAT, EYE WASH AND SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
SULFURIC ACID SOLUTION, UN 1830.
================== Physical/Chemical Properties ==================
HCC:C1
Boiling Pt:B.P. Text:28.4F,-2.0C
Spec Gravity:1.03
Solubility in Water:MISCIBLE.
Appearance and Odor:CLEAR, COLORLESS LIQUID, SULFURIC ACID IS OILY.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
BASES, OXIDIZERS, ORGANIC MATERIALS, HALOGENS OR INTERHALOGENS, LITHIUM
NITRATE, METAL ACETYLENES, METAL OXIDES, METALS.
Stability Condition to Avoid:CAN REACT WITH POWDERED METALS TO FORM
FLAMMABLE HYDROGEN GAS.
Hazardous Decomposition Products:OXIDES OF SULFUR, WILL REACT WITH
WATER OR STEAM TO PRODUCE TOXIC AND CORROSIVE FUMES.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS. ALWAYS CONTACT A PERMITTED
WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.